The 3-phase power and mains disturbance analyzer MAVOWATT 30 fulfills the standards EN50160, EN61000-4-7 and EN61000-4-15 which are relevant for mains quality measurement, as well as EN61000-4-30 which specifies measuring procedures for voltage quality. The class A device simultaneously monitors RMS values, harmonics, flicker and transients down to a time range of approximately 80 µs
Power and mains disturbance analysis 3 Years Warranty
Harmonic analysis per EN 61000-4-7
Mains quality per EN50160 with statistic bar chart
Flicker analysis per EN 61000-4-15
8 measuring channels: 4 for voltage (differential) and 4 for current (current sensor), for measurements at 50 / 60 Hz power frequency
Data storage to Compact Flash memory cards ≥4 GB (scope of supply)
Power supply via charging device 90..264 V / 47..63 Hz
Built-in accumulator for up to 3 hour operating time
Optional RS232, USB or LAN interface
Optional current measuring accessories
High performance DranView PC analysis and evaluation software is available